Prolactin can occasionally be present in serum in a macromolecular complex. The most common form is macroprolactin, an antibody-antigen complex of prolactin and immunoglobulin G with a molecular mass of 150-170kDa. Macroprolactin can be detected by the prolactin assay but is cleared more slowly than prolactin from the circulation leading to an apparent hyperprolactinaemia.
Macroprolactin has minimal bioactivity in-vivo, which is thought to be due to the failure of the high-molecular mass complex to cross capillary membranes to reach the prolactin receptors. It is important macroprolactin is identified when it is the cause of apparent hyperprolactinaemia to avoid diagnostic confusion and possible inappropriate treatment.
All samples with prolactin greater than 700 mU/L are automatically tested for macroprolactin unless clinical details indicate a known cause for elevation, e.g. prolactinoma.
Repeat testing is not indicated if the patient has been tested for macroprolactin within the last 12 months and the total prolactin result has not significantly changed.
The sample is put through Polyethylene Glycol (PEG) precipitation which physically removes the protein-complexed prolactin. The sample is then reanalysed for prolactin. Those where the results are significantly different are said to have macroprolactin present.
Reporting of Post PEG monomeric Prolactin level helps in identifying true monomeric (biologically active) hyperprolactinaemia from macroprolactinaemia (biologically inactive) to avoid potential misdiagnosis and mismanagement.
None
Reference ranges for Monomeric Prolactin are as follows:
Male: 32-309 mIU/L
Female: 39-422 mIU/L (non-pregnant)
Copyright UHB Pathology 2018
Protection of Personal Information – Clinical Laboratory Services comply with the Trust Data Protection Policy and have procedures in place to allow the Directorate and it’s employees to comply with the Data Protection Act 1998 and associated best practice and guidance.
University Hospitals Birmingham medical laboratories at Queen Elizabeth Hospital, Heartlands Hospital, Good Hope Hospital and Solihull Hospital are UKAS (United Kingdom Accreditation Service) accredited to the ISO 15189:2012 standard. For a list of accredited tests and other information please visit the UKAS website using the following link: https://www.ukas.com/find-an-organisation/
Tests not appearing on the UKAS Schedule of Accreditation currently remain outside of our scope of accreditation. However, these tests have been validated to the same high standard as accredited tests and are performed by the same trained and competent staff.
For further test information, please visit the test database: http://qehbpathology.uk/test-database
For further information contact Louise Fallon, Quality Manager, 0121 371 5962