Written by Super User on . Posted in Clinical Services / Interpretation of Results

Monitoring glycaemic control in patients with diabetes

HbA1c is routinely measured for this purpose. The assay is run daily on weekdays and requires an EDTA plasma sample (purple top). Fructosamine can be used as an alternative when HbA1c is not appropriate. Fructosamine reflects blood glucose over two weeks rather than 2 to 3 months as it reflects glycation of albumin rather than haemoglobin. Fructosamine is performed on serum (yellow or red top) and run daily.

UHB, Clinical Chemistry